Rat Procalcitonin (PCT) ELISA Kit Instructions

Rat Procalcitonin (PCT) Enzyme Linked Immunosorbent Assay Kit User Manual Xiamen Huijia Biotechnology Co., Ltd. This kit is for in vitro research use only, not for clinical diagnosis! It is expected to use ELISA to quantitatively determine rat serum and plasma Or PCT content in other relevant biological fluids. Experimental principle Microporous plates are coated with purified PCT antibody to make a solid-phase carrier. Specimens or standards, biotinylated PCT antibody and HRP-labeled avidin are added to the microwells in sequence. (TMB) color development. TMB is converted into blue under the catalysis of peroxidase, and into the final yellow under the action of acid. The color depth is positively correlated with the PCT in the sample. Measure the absorbance (value) at 450nm with a microplate reader to calculate the sample concentration. Kit composition and reagent preparation 1. Enzyme microplate: one piece (96 wells) 2. Standard product (lyophilized product): 2 bottles, please prepare within 15 minutes before use. Each bottle is diluted to 1ml with the sample diluent, and after being capped, it is allowed to stand at room temperature for about 10 minutes. At the same time, it is inverted / rubbed repeatedly to help dissolve. Its concentration is 1,000 pg / ml, and then do serial dilutions (Note: Do not directly Do multiple dilutions in the plate), and make up to 1,000 pg / ml, 500 pg / ml, 250 pg / ml, 125 pg / ml, 62.5 pg / ml, 31.2 pg / ml, 15.6 pg / ml, and the sample diluent directly 0 pg / ml as a blank well. For example, to prepare a 500 pg / ml standard: take 0.5 ml (not less than 0.5 ml) of 1,000 pg / ml of the above standard into an Eppendorf tube containing 0.5 ml of sample diluent, mix well, and the rest of the concentration can be deduced by analogy. 3. Sample diluent: 1 × 20ml. 4. Test dilution A: 1 × 10ml. 5. Test diluent B: 1 × 10ml. 6. Detection solution A: 1 × 120 per bottle (1: 100). Before use, dilute with Test Diluent A 1: 100 (for example: 10 Test Solution A / 990 Test Diluent A), mix thoroughly, and prepare according to the pre-calculated total amount required for each experiment (100 / Hole), more 0.1-0.2ml should be prepared during actual preparation. 7. Detection solution B: 1 × 120 per bottle (1: 100). Dilute 1: 100 with test dilution B immediately before use. The dilution method is the same as that of Test Solution A. 8. Substrate solution: 1 × 10ml / bottle. 9. Concentrated washing liquid: 1 × 30ml / bottle, each bottle is diluted 25 times with distilled water. 10. Stop solution: 1 × 10ml / bottle (2 mol / L H2SO4). 11. Membrane: 5 sheets 12. Instructions for use: 1 self-supplied article 1. Microplate reader (recommended to preheat the instrument before use) 2. Micro-liquid dispenser and pipette tip, EP tube 3. Distilled or deionized water , Collection and storage of filter paper specimens 1. Serum: Whole blood specimens should be left at room temperature for 2 hours or 4 overnight and then centrifuged at 1000g for 20 minutes. Take the supernatant for detection, or store the supernatant at -20 or -80 However, repeated freezing and thawing should be avoided. 2. Plasma: EDTA or heparin can be used as an anticoagulant. Centrifuge the sample at 1000g for 15 minutes within 30 minutes after collection. Take the supernatant for detection, or store the supernatant at -20 or -80, but avoid repeated freezing. melt. 3. Other biological specimens: centrifuge at 1000g for 20 minutes, take the supernatant for testing, or store the supernatant at -20 or -80, but avoid repeated freezing and thawing. Note: The above specimens should be sealed and stored, 4 should be stored for less than 1 week, -20 should not exceed 1 month, -80 should not exceed 2 months; specimen hemolysis will affect the final test results, so hemolysis specimens should not be tested . Before starting the experiment, all reagents should be equilibrated to room temperature, and the reagents should not be dissolved directly at 37; when preparing the reagents or samples, they should be thoroughly mixed. Try to avoid foaming when mixing. The sample content should be predicted before the experiment. If the sample concentration is too high, the sample should be diluted to make the diluted sample meet the detection range of the kit, and then multiplied by the corresponding dilution factor when calculating. 1. Add sample: set blank hole, standard hole and sample hole to be tested respectively. Add sample diluent 100 to the blank well, and add the standard or the sample to be tested 100 to the remaining well. Be careful not to have air bubbles. When adding the sample, add the sample to the bottom of the enzyme plate. Try not to touch the wall of the well. Gently shake to mix the enzyme. Cover or cover the target plate and incubate at 37 for 2 hours. To ensure the validity of the experimental results, please use a new standard solution for each experiment. 2. Discard the liquid and dry it without washing. Add 100 working solution of detection solution A (prepared before use) to each well, add the microplate to the membrane, and incubate at 37 for 1 hour. 3. Discard the liquid in the hole, spin dry, wash the plate 3 times, soak for 1-2 minutes each time, about 400 / per hole, spin dry (you can also pat the liquid in the hole dry). 4. Add 100 working solution of test solution B (prepared before use) to each well, add a film, and incubate at 37 for 1 hour. 5. Discard the liquid in the well, spin dry, wash the plate 5 times, the method is the same as step 3. 6. Add substrate solution 90 to each well, enzyme label plate and film 37 to avoid color development (the reaction time is controlled at 15- 30 minutes, when the first 3-4 wells of the standard well have a clear gradient blue, and the gradient of the last 3-4 wells is not obvious, it can be terminated). 7. Add stop solution 50 to each well to stop the reaction. At this time, the blue color turns to yellow. The order of adding the stop solution should be the same as that of the substrate solution. 8. Immediately measure the optical density (value) of each well with a microplate reader at 450nm wavelength. Note: 1. Reagent preparation: All reagents should be equilibrated to room temperature before use. Please save the reagents according to the instructions immediately after use. Please use disposable tips during the experiment to avoid cross contamination. 2. Sample addition: when adding samples or adding reagents, if the time interval between the first well and the last well is too large, it will result in different "pre-incubation" time, which will obviously affect the measured value Accuracy and repeatability. The time of one sample addition (including standard and all samples) is best controlled within 10 minutes. It is recommended to set up multiple holes for experiments. 3. Incubation: In order to prevent the sample from evaporating, place the enzyme-labeled plate with a cover or membrane in the wet box during the experiment to avoid liquid evaporation; the next step should be performed as soon as possible after washing the plate, and should be avoided at any time The microplate is in a dry state; at the same time, the given incubation time and temperature should be strictly observed. 4. Washing: The washing liquid remaining in the reaction well during the washing process should be patted dry on the filter paper. Do not put the filter paper directly into the reaction well to absorb water. At the same time, the remaining liquid and fingerprints on the bottom of the plate should be eliminated to avoid affecting the final enzyme label. Instrument reading. 5. Preparation of reagents: before using, please shake the hands a few times or centrifuge for a while to prevent the liquid on the tube wall or bottle cap from depositing to the bottom of the tube. Standard products, working solution A, and working solution B should be prepared according to the required amount, and prepared with the corresponding diluent, not to be confused. Please accurately prepare the standard products and working solutions, and try not to prepare them in a small amount (such as when drawing the test solution A, it should not be less than 10 at a time) to avoid concentration errors due to inaccurate dilution; do not reuse the diluted standard products and test Solution A working fluid, detection solution B working fluid. 6. Control of reaction time: Please observe the color change of the reaction well regularly after adding the substrate (for example, every 10 minutes). If the color is dark, please add the stop solution in advance to stop the reaction to avoid the reaction being too strong and affecting the microplate reader. Optical density reading. 7. Substrate: Please keep the substrate away from light, and avoid direct exposure to strong light during storage and incubation. Plate washing method 1. Manual plate washing method: Inject at least 0.4ml of the recommended washing buffer into the well, soak for 1-2 minutes, aspirate (do not touch the wall) or shake off the liquid in the microplate, on the experimental bench Paved with several layers of absorbent paper, and slammed down the enzyme plate several times; repeat this process as many times as needed. 2. Automatic plate washing: If there is an automatic plate washing machine, it should be used in the formal experiment process after being used proficiently. Specificity This kit can simultaneously detect recombinant or natural rat PCT without cross-reactivity with other related proteins. Calculate the value of each standard and sample after deducting the blank hole value (7-point diagram). If multiple holes are set, the average value should be taken. Taking the concentration of the standard product as the ordinate (logarithmic coordinate) and the value as the abscissa (logarithmic coordinate), draw a standard curve on the logarithmic coordinate paper. It is recommended to use professional curve making software for analysis, such as curve expert 1.3, according to the sample value, find the corresponding concentration from the standard curve, and multiply it by the dilution factor; or use the concentration and value of the standard to calculate the regression equation of the standard curve, and then the sample The value of is substituted into the equation, the sample concentration is calculated, and then multiplied by the dilution factor, which is the actual concentration of the sample. Detection range: 15.6 pg / ml-1,000 pg / ml, please draw the following concentration values ​​for drawing the standard curve: 1,000 pg / ml, 500 pg / ml, 250 pg / ml, 125 pg / ml, 62.5 pg / ml, 31.2 pg / ml, 15.6 pg / ml. Minimum detection limit: 3.9 pg / ml means that due to the existing conditions and the level of science and technology, it is not possible to comprehensively identify and analyze all raw materials provided by all suppliers. This product may have certain quality and technical risks. The final experimental results are closely related to the effectiveness of the reagents, the relevant operations of the experimenter, and the experimental environment at the time, so be sure to prepare sufficient specimen backups. Only all reagents are used to ensure the detection effect, because all reagents are related and cannot be mixed with other manufacturers' products. Only by strictly following the experimental instructions of the reagents will the best test results be obtained. 4. Avoid exposing the reagent to strong light during storage and incubation. All reagent bottle caps must be tightly closed to prevent evaporation and microbial contamination, because the interference of proteolytic enzymes will lead to erroneous results. 5. Storage of the kit: Please save the standard, detection solution A and detection solution B at -20 as soon as possible after receiving the kit, and place the remaining reagents at 4 for short-term storage and -20 for long-term storage. After opening, the microplate should be sealed and desiccated and stored at -20 to avoid moisture. 6. Salt will be precipitated from the concentrated washing liquid, which can be heated and dissolved in the water bath when diluted. 7. There may be a little water-like substance in the well of the enzyme-linked plate just opened. This is a normal phenomenon and will not have any impact on the experimental results. 8. Validity: 6 months. 9. These operating instructions apply to the 48T kit, but all reagents in the 48T kit are halved.

Modern Desk

Mid Century Modern Desk,Modern Office Desk,Modern Computer Desk,Contemporary Desk

BOSA FURNITURE CO.,LTD. , https://www.bosafurniture.com

This entry was posted in on